Zemic / H10G2 Beam Load Cell ZEMIC Load Cell
Availability:
In Stock
Brand: ZEMIC
H10G2 Beam Load Cell ZEMIC Load Cell
Product Description

Short Description:
◎Nickel plated alloy steel IP68 dual shear beam load cell;
◎High accuracy;
◎Suitable for truck and track scales and other heavy weighing devices;
◎Hermetically sealed;
Available models:
| Capacity |
Full article description |
| 12.5klb |
H10G2-12.5K-10 |
| 12.5klb |
H10G2-12.5K-13 |
| 12.5klb |
H10G2-12.5K-16 |
| 16.5klb |
H10G2-16.5K-19 |
Specification:
| No. for products type |
|
-0.048076923 |
-19 |
| Maximum capacity ( Emax ) |
klb |
12.5K |
16.5K |
| Output sensitivity ( = FS ) |
mV/V |
0.500±0.01mV/V(@12.5K) |
0.5291±0.01mV/V(@13228lb) |
| Accuracy class |
|
G10 |
| Combined error |
%FS |
±1.0 |
±1.0 |
| Hysteresis |
%FS |
±1.0 |
±1.0 |
| Non-repeatability |
%FS |
±0.1 |
±0.1 |
| Creep(20min) |
%FS |
±0.1 |
±0.1 |
| Zero balance |
%FS |
±2.0 |
±2.0 |
| Compensated temperature |
℃ |
-10~+40 |
| Operating temperature |
℃ |
-35~+65 |
| Temperature effect on sensitivity |
%FS/10℃ |
±0.36 |
| Temperature effect on zero |
%FS/10℃ |
±0.2 |
| Input resistance |
Ω |
415±30 |
| Output resistance |
Ω |
350±3.5 |
| Insulation resistance |
MΩ |
≥ 5000 |
| Excitation, recommended voltage |
V |
5~12(DC) |
| Excitation maximum |
V |
18(DC) |
| Safe overload |
of Emax |
150 |
| Ultimate overload |
of Emax |
300 |
Dimensions in mm:

Wiring:
◎-10: adopt 4 conductor cable with standard connector;
◎-16: adopt 4 conductor cable with square connector. Standard cable length: 10m;
◎-13/-19: adopt 4 conductor cable with twin connectors. Standard cable length: 1m;
Product has been added to your cart
Compare
(0)