Single point load cell 50-2000kg
The ZMPF is a single point load cell made from alloy steel. The load cell is suitable for bench scales, platform scales and weighing machines with accuracy C3. The load cell gives extremely accurate reproducible results, over a long term even in harsh industrial environments. Each individual load cell ZMPF is corner adjusted and optimised for out of center load sensitivity. This ensures that there will be no measurement error when the load is placed off centre, eg in a corner of a platform.
Dimensions in mm

Technical Specifications
| PARAMETER | VALUE | UNIT |
| Standard capacities (Emax) | 50-2000 | KG |
| Rated output-R.O. | 2.0 | mV/V |
| Zero balance | 1 | ±% of rated output |
| Non linearity | 0.03 | ±% of rated output |
| Hysteresis | 0.03 | ±% of rated output |
| Non-repeatability | 0.02 | ±% of rated output |
| Creep error (30 minutes) | 0.03 | ±% of rated output |
| Zero return (30 minutes) | 0.03 | ±% of rated output |
| Temperature effect on min. dead load output | 0.0026 | ±% of rated output/℃ |
| Temperature effect on sensitivity | 0.0015 | ±% of rated output/℃ |
| Compensated temperature range | -10 to +40 | ℃ |
| Operating temperature range | -20 to +60 | ℃ |
| Safe overload | 150 | % of R.C |
| Ultimate overload | 200 | % of R.C |
| Excitation, recommended | 10 | Vdc |
| Excitation, maximum | 15 | Vdc |
| Input resistance | 360±10 | Ohms |
| Output resistance | 350±3 | Ohms |
| Insulation resistance | 5000 | Mega-Ohms |
| Material | Alloy steel | |
| Protection class | IP66 |