Models

FA5124

Features

Accuracy:C3
IP:IP65
Material:Aluminium Alloy

Dimensions

Specifications

Item Unit Specification
Maximum Capacity (Emax) kg 50, 60, 80, 100, 150, 200, 250, 300, 400, 500
Output Sensitivity (=FS) mV/V 2.0 ± 0.2
Accuracy Class – C3
Combined Error %FS ±0.02
Creep (30min) %FS ±0.0167
Temp. Effect on Sensitivity %FS / 10℃ ±0.0175
Temp. Effect on Zero %FS / 10℃ ±0.02
Zero Balance %FS ±2
Compensated Temp. Range ℃ -10 ~ 40
Operating Temp. Range ℃ -35 ~ 65
Input Resistance Ω 406 ± 6
Output Resistance Ω 350 ± 3
Insulation Resistance MΩ / 50VDC ≥5000
Recommended Excitation VDC 5 ~ 12
Maximum Excitation VDC 18
Safe Overload %FS 120
Ultimate Overload %FS 150
Protection Class – IP65
Cable Specifications mm Φ5.9
Cable Length m 3
Recommended Installation Size mm 600×600 (50200kg)600×800 (250500kg)1200×1200 (750~2000kg)
Corner Deviation % load/100mm ≤0.02
Recommended Fixing Torque N·m M12: 100N·m (50–500kg)M16: 160N·m (750–2000kg)
Wiring Color Code – Red: Input+
Brown: Sense+
Blue: Output+
Black: Sense−
Yellow: Input−
White: Output−
Shield: Transparent