Digital indicator CSD-904-EX
Features
・Best for scales, to 6000 div. (at the input of 0.2 micro-V/d or more.)
・Measurement value display with large-scale fluorescent display 22mm character height.
・Full six digit (999 999) can be displayed.
・Unit (t, kg, g, lb) displayed.
・Built-in linear riser (three points or less)
・Weigh-in/Weigh-out mode
・Multiple I/O functions Serial interface, BCD, RS-232C, RS-422/485, 0 to 10 V, 4 to 20 mA
・Protection grade : IP65
-
Specification name
Specification contents
Bridge power supply 5 VDC±0.25VDC 120 mA with sensing function Input sensitivity 0.2 μV/dor more (d= minimum scale) Input range -3.1 mV/V ~ 3.1 mV/V Zero adjustment range -2.5 mV/V ~ 2.5 mV/V Non-linearity 0.01 %F.S. Temperature effect Zero point ±0.2 μV/℃, Sensitivity ±0.0015 %F.S./℃ (during a calibration at the input sensitivity 0.2micro-V/d or more) Load display Display gross weightor Net weight A/D sampling speed 15 times/s Display range -999 999 ~ 999 999 Condition display ACCUM, MD, PT, TARE, GROSS, NET, ZERO Judgement display HI, OK, LO (OK : Green fluorescent display tube, HI/LO : Orangefluorescent display tube) Display times 5 times/s (Changeable to 15 times/s) Decimal point display Changeable to No display, 10¹, 10² or 10³ Unit display Changeable to g, kg, t or lb (Green fluorescent display tube) Operating temp.
/humidity rangeTemperature -10 ℃ ~ 40 ℃, Humidity 85 %RH or less (Non condensing) Power supply voltage 100 VAC (85 VAC ~ 110 VAC) 50/60 Hz Power consumption Approx. 4 VA Outline dimensions
(WxHxD)192 mm x 96 mm x 165 mm (excludes protruding parts) Weight Approx. 1.6 kg (without options) Protection code IP65 or equivalent (Only for the fron panel when the attached panel mounting gascket is installed.